| HVA
30 - VLF and DC Hipot Instrument |
|
|
|
|
|
|
The
single piece HVA30 is not only the
most advanced high voltage VLF
(Very Low Frequency) test system
available; it is also the
lightest, most compact instrument
of its type on the market.
|
|
Although
primarily designed for the AC
Hipot testing of extruded Medium
Voltage cable systems - according
to the new IEEE400 and
international testing standards
where the application of high
voltage DC is no longer
recommended - the multi-output
HVA30 is also suitable for testing
transformers, switchgear, rotating
machines and other electrical
apparatus.
|
|
The
instrument offers fully automatic
Testing Sequences which allow the
operator to effortlessly apply the
correct testing standards without
having to remember what those
testing parameters are, thus
avoiding possible over stressing
of the cable system.
|
|
|
|
|
| Standard
features like built in storage of
test results, smooth load
independent and symmetrical
Sinewave HV outputs, DC and AC VLF
outputs, capacitance and
insulation resistance
(mega-ohmmeter) measurements,
accurate RMS metering, integrated
discharge and transient
protection, all make this
instrument the most sophisticated
and easiest to use VLF instrument
available. |
|
|
Optional
items include a small portable
power pack to supply the HVA30
when a standard 110V AC mains
supply is not available. No other
VLF unit on the market offers this
option!
In
addition a portable Tan Delta
system can be used with the HVA30
for additional cable testing and
cable diagnostic capabilities. |
|
|
|
 |
Smallest,
lightest, most advanced
universal high voltage |
|
test
instrument available. |
 |
VLF
(0.1Hz), DC (+/-), Cable
Fault Conditioning (Burning)
and
Sheath/Jacket Testing
|
|
modes
all included. |
 |
Fully
Automatic or manual cable
test sequences |
 |
True
Symmetrical Sinusoidal, load
independent, output waveform across
the full |
|
load
range. |
 |
Real-time
display of actual output
waveform |
 |
Easy
to use, ergonomic, menu
guided, large backlit user
interface |
 |
Rugged,
one-piece design for easy
portability |
 |
Large
output load capability (up
to 5uF) |
|
|
|
|
See
the Datasheet
for
more Technical Information
|
|
|
|
|
|
|
|
|
|