APPLICATIONS |
|
|
|
The
HVA30 provides the testing and commissioning engineer with a versatile high
voltage power source suitable for testing electrical plant including cables:
XLPE, PE, EPR, PILC etc, capacitors, switchgear, transformers, rotating
machines, insulators and bushings. The HVA30/5
provides increased power for the longer cable runs. |
|
|
|
DESCRIPTION |
|
|
|
It
is well known that DC testing of aged extruded cable such as XLPE and EPR is
potentially damaging to the cable insulation causing premature failure of the
cable under service conditions. Any form of DC testing has been found to be
ineffective in detecting even serious faults in such cables. It is because of
these limitations that International and National bodies such as CENELEC, VDE,
SABS and the IEEE now recommend testing utilising low frequency AC test systems.
VLF testing enables the cable test engineer to detect insulation defects before
the cable fails in service. |
|
|
| PRODUCT
DESIGN |
|
| The HVA30
has a very advantageous power / weight ratio. At 50kgs the HVA30/5
is one the lightest VLF test systems of its rating available today. Apart from
the VLF output the HVA30/5 can also produce either polarity DC
together with a cable sheath /jacket testing modes. The output test sequences,
which are easily set by the operator, can be either set manual or fully
automatic operation. In the VLF mode the HVA30/5 will output 23kV RMS
into a 0.5µF at 0.1Hz. However, as the VLF frequency can be adjusted, loads
of up to 2.5µF can be tested with an output frequency of 0.02Hz. The output
VLF waveform is load independent and symmetrical thus avoiding destructive
space charge effects caused by DC polarisation. To further assist the operator
the HVA30/5 will automatically calculate the optimum output frequency
for larger loads. All test results are stored on a on-volatile memory for
downloading to a PC for review and analysis. |
|
| FEATURES: |
|
|
- Lightweight
portable unit
- Solid
state air insulated design
- True
sine wave low frequency output
- Suitable
for VLF, DC and Jacket/ sheath testing
- Fault
conditioning capability
- Test
result storage capability
- Full
short circuit protection with arc management regulation
- Provides
compliance with CENELEC, IEEE 400.2, VDE 0296 and other international standards
- Manual
or fully automatic test sequence selection .Real-time display of actual
output waveform
|
|
|
|
|
|
|
|
| |